Intrinsically safe temperature probe with iTHERM QuickNeck for fast disassembly of the insert
Especificações resumidas
Accuracy
Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
fastest response time with thermowell t90 starting at below 10 s depending on configuration
Max. process pressure (static)
depending on the configuration up to 100 bar
Operating temperature range
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
iTHERM ModuLine TM131 is a modular metric RTD or TC thermometer with protection tube or to be used with onsite thermowell. It is suitable for every application, from basic functionality to high-end performance across all industries.
For universal use across all industries: From heavy industries (Power & Energy, Chemical, Oil & Gas) to utility applications.
International certification: e.g. explosion protection according to ATEX, IECEx, CSA C/US and NEPSI.
iTEMP temperature transmitter with all common communication protocols and optional Bluetooth® connectivity.
Benefícios
Modular configuration for all applications: A wide selection of components and innovations, all combined under a single order code.
Increased efficiency: Fastest response times with QuickLink thermowell and optimal thermal coupling or iTHERM QuickSens sensor design.
Enhanced safety: Reliability in demanding applications with iTHERM StrongSens and highest vibration-resistance or Dual Seal second process barrier.
Para enfrentar os desafios do monitoramento de temperatura em processos tão críticos, foi desenvolvido um design de poço para termoelemento que responde às mudanças no processo até cinco vezes mais rápido do que as versões padrão.
O processo Ziegler-Natta utiliza produtos químicos perigosos, como o tetracloreto de titânio. A medição precisa da temperatura é crucial para evitar reações descontroladas e garantir a segurança e a eficiência.
Medição da temperatura rápida e não invasiva, sem remover isolamento para calibração: iTHERM SurfaceLine TM611 reduz o tempo de inatividade, melhora a segurança e entrega resultados precisos mesmo em áreas classificadas.
Torishima projeta e constrói grandes sistemas de água de resfriamento para clientes no Oriente Médio, confiando na instrumentação da Endress+Hauser pela qualidade e desempenho de seus produtos.
Explore iTHERM ModuLine industrial thermometers and thermowells. Learn more about the technical differences between the different models and discover included Endress+Hauser innovations.
O iTHERM ModuLine oferece flexibilidade total para medição de temperatura industrial. Os sensores de temperatura industriais modulares podem ser configurados individualmente para atender às necessidades do seu processo.
metric style modular temperature assembly universal range of application suitable for hazardous areas with neck or iTHERM QuickNeck incl. thermowell / protection tube (metal) or to be installed into thermowell can be used with iTHERM StrongSens, iTHERM QuickSens insert for fast response times
Thermowell / protection tube
welded protection tube or to be used with thermowell
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
Thermowell: 9x1,25 mm 11x2 mm 12x2,5 mm 14x2 mm 16x3,5 1/4" SCH80 1/2" SCH80 1/2" SCH40
straight reduced tapered optimized for quick response times
Surface roughness Ra
< 0.76 μm (0.03 μin)
Operating temperature range
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
Max. process pressure (static)
depending on the configuration up to 100 bar
Accuracy
Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
fastest response time with thermowell t90 starting at below 10 s depending on configuration
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
ATEX Ex ec, Ex tc ATEX IECEx Ex ta/tb, Ex ia, Ex db CSA C/US IS, NI, XP, DIP INMETRO Ex ia, Ex d, Ex tb NEPSI Ex ia, Ex d, Ex tD EAC Ex d, Ex ta/tb, Ex ia UKCA Ex ia, Ex nA, Ex tc KC Ex ia
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex