This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
- F
- L
- E
- X
SS2000 single channel gas analyzer measures H2O or CO2 and are virtually maintenance-free
- F
- L
- E
- X
- F
- L
- E
- X
SS2000 mounted on a panel
- F
- L
- E
- X
SS2000XP Class I, Div 1 Groups B, C, and D
SS2000 single channel gas analyzer measures H2O or CO2 and are virtually maintenance-free
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
TDLAS
-
Product Headline
Single channel gas analyzer for moisture (H2O) in the natural gas industry. The sensor measures gas using tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
H2O (Moisture):
0 to 100 ppmv (minimum)
0 to 5000 ppmv (maximum) -
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
-
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 700 to 1400 mbara -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
100 to 240 VAC, 50 to 60 Hz
or
9 to 16 VDC or 18 to 32 VDC - optional
1 Amp maximum at 120 VAC
1.6 Amp at 24VDC, 3.2 Amp at 12 VDC -
Communication
Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s) -
Housing materials
Electronics: 304 stainless steel (Class I Division 2)
Electronics: Cast Aluminum (Class I Division 1)
Sample System Panel: Anodized aluminum -
Hazardous area approvals
CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
Type 3R (Class I Division 2)
Type 4 (Class I Division 1)
-
Measuring principle
TDLAS
-
Product Headline
Single channel gas analyzer for carbon dioxide (CO2) in the natural gas industry. The sensor measures gas using tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
CO2 (Carbon Dioxide):
0 to 5% volume (minimum)
0 to 50% volume (maximum) -
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
-
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 700 to 1400 mbara -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
100 to 240 VAC, 50 to 60 Hz
or
9 to 16 VDC or 18 to 32 VDC - optional
1 Amp maximum at 120 VAC
1.6 Amps at 24 VDC, 3.2 Amps at 12 VDC -
Communication
Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s) -
Housing materials
Electronics: 304 stainless steel (Class I Division 2)
Electronics: Cast Aluminum (Class I Division 1)
Sample System Panel: Anodized aluminum -
Hazardous area approvals
CSA Class I, Division 1
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
Type 3R (Class I Division 2)
Type 4 (Class I Division 1)
-
-
Technical Information (TI)
SS2000/SS2000XP TDLAS Gas Analyzer
-
Technical Information (TI)
English version - 09/2021New version available in EnglishSystem design and specification for the SS2000/SS2000XP TDLAS Gas
AnalyzerLanguage:
English
Version:
14/09/2021
File size:
1.1 MB
File name:
TI01644CEN_01.21.pdf
-
-
-
Device Parameter (GP)
HC 12 firmware Description of device parameters
-
Device Parameter (GP)
English version - 08/2024New version available in EnglishExpert-level description and operational information for
device parametersLanguage:
English
Version:
02/08/2024
File size:
2.1 MB
File name:
GP01181CEN_0224.pdf
-
-
-
Installation Instructions (EA)
Installation Instruction
-
Installation Instructions (EA)
English version - 02/2022New version available in EnglishInstallation Instruction for SS2000XP Floating Ground Re-Work Kit
Language:
English
Version:
15/02/2022
File size:
1.8 MB
File name:
EA01421CEN 0122.pdf
-
-
-
Ex Safety Instruction (XA)
SS500/SS2000/SS3000, SS500e/SS2000e/SS3000e and SS500XP/SS2000XP Safety Instruction
-
Ex Safety Instruction (XA)
English version - 10/2021New version available in EnglishSafety Instructions for the SS500/SS2000/SS3000,
SS500e/SS2000e/SS3000e and SS500XP/SS2000XP TDLAS Gas AnalyzersLanguage:
English
Version:
04/10/2021
File size:
2 MB
File name:
XA02744CEN_01.21.pdf
-
-
-
Special Documentation (SD)
AMS100 Software Operating Instructions
-
Special Documentation (SD)
English version - 05/2023New version available in EnglishInstructions for operating the AMS100 software as an
alternative method for TDLAS gas analyzer system configurationEN 10/05/2023Language:
English
Version:
10/05/2023
File size:
1.3 MB
File name:
SD02863CEN_0223.pdf
-
-
-
AI (Application note)
CO2 in natural gas production, storage, transportation and distribution
-
AI (Application note)
English version - 09/2021New version available in EnglishThis application note explains the use of TDLAS technology to measure
CO2 in pipelines in the natural gas supply chain.Language:
English
Version:
13/09/2021
File size:
211.3 KB
File name:
AI01216CEN_0121.pdf
-
-
-
AI (Application note)
H2O in natural gas production, storage, transportation and distribution
-
AI (Application note)
English version - 08/2023New version available in EnglishThis application note explains the use of TDLAS technology to measure
water moisture in pipelines in the natural gas supply chain.Language:
English
Version:
21/08/2023
File size:
237.5 KB
File name:
AI01215CEN_0123_v4.pdf
-